E1100n
/in AC Highvoltage Power Supplies /by adm1n1strat0rE1100 OEM HV Power Supply
A simple Highvoltage Power Supply to connect one ioniser/bar.
Operating output: +/- 5,5kV A very simple HV power supply for neutralisation with 1 ioniser. The E1100 is a reliable generator for HV to power 1 ioniser with a cable length of up to 8m*! Choice of case body color or own logo print on request.Application
Specialities
+49 7628 35 94 064
We gladly help you to solve your problem.
E1100 Specifications
- Power input: 230V AC 50/60Hz; 115V AC 60Hz
- Power consumption: 40VA max.
- Output: max. 5mA at 5,5 kV
- Auto-shut-down at 5mA
- Illuminated power switch
- Bajonet connector for 1 ionisers
- Cable length per unit*: max. 8 m minus length of bar x 1,5
- Powder coated steel case IP54 with mounting brackets for walls
- Choice of case color or own logo print on request
- CE qualification
Simple HV power supply with good performance
Robust, industry-proof design
Easy and flexible mounting
For up to 2 ionisers
No specific accessories.
For mounting aides and instructions consult us.
*We gladly offer direct assistance for topics around power, cable length and calculations!
All products within this product category:
E2100
/in AC Highvoltage Power Supplies /by adm1n1strat0rE2100 OEM HV Power Supply
A simple Highvoltage Power Supply to connect two ionisers/bars.
Operating output: 5,5kV A robust HV power supply unit for use when 2 ionisers need to be powered. The E2100 is reliably generating the required highvoltage to connect up to 2 ionisers with up to 15 m cable length*! Choice of case color or own logo print on request.Application
Specialities
+49 7628 35 94 064
We gladly help you to solve your problem.
E2100 Specification
- Power input: 230V AC 50/60Hz; 115V AC 60Hz
- Power consumption: 40VA max.
- Output: max. 5mA at 5,5 kV
- Auto-shut-down at 5mA
- Illuminated power switch
- Bajonet connectors for up to 2 ionisers
- Cable length per unit*: max. 15 m minus length of bar x 1,5
- Powder coated steel case IP54 with mounting brackets for walls
- Choice of case color or own logo print on request
- UL, CE and CB certified
Simple HV power supply with good performance
Robust, industry-proof design
Easy and flexible mounting
For up to 2 ionisers
No specific accessories.
For mounting aides and instructions consult us.
*We gladly offer direct assistance for topics around power, cable length and calculations!
All products within this product category:
E3100
/in AC Highvoltage Power Supplies /by adm1n1strat0rE3100 Standard HV Power Supply
The HV Power Supply for several also longer bars and cables.
Operating output: +/- 6 kV An HV power supply unit with good performance wherever more than 1 ionisers are required for neutralisation. The E3100 is generating the highvoltage for up to 4 anti-static devices with up to 30 m cable length*!Application
Specialities
+49 7628 35 94 064
We gladly help you to solve your problem.
E3100 Specification
- Power input: 230V AC 50/60Hz; 115V AC 60Hz
- Power consumption: 40VA max.
- Output: max. 5mA at +/- 6 kV
- Auto-shut-down at 5mA; unit switches automatically on when overcharge is reduced
- Illuminated power switch
- Bajonet connectors for up to 4 ionisers
- Cable length per unit*: max. 30 m minus length of bars x 1,5
- Powder coated steel case IP54 with mounting brackets for walls
- UL, CE and CB certified
Top HV power supply with top performance
Robust, industry-proof design
Easy and flexible mounting
Can be integrated into process control system
Low maintenance
Variant ATEX Bars
Variant for EX1250 antistatic bars with ATEX certification
The E3100-EX is designed specifically for the use with the ex-proof Antistatic Bar EX1250. The difference to the standard HV power supply E3100 is only in technical constraints and fuse with regard to the follwong specifications: the E3100-EX is limited to 20 VA power consumption and 5mA output; output voltage is 6 kV with a max. peak at 7,75 kV. The fuses are laid out for 800 mA at 115V and 400 mA at 230 V.
NOTE: the power unit itself is NOT ex-proof and requires installation outside the hazardous area. The max. allowed current for the ATEX certification is 5 mA. Consequently, per power unit a maximum of 30 m cable minus 1,5 times the length of the bar(s)*. This equates for example to:
- 2 antistatic bars of 1 m length and each with 11,5 m cable
- 3 antistatic bars of 1 m length and each with 7 m cable
- 4 antistatic bars of 0,75 m length and each with 5,5 m cable
- etc.
Variant Harting Connector
Variant for powering via Harting connector
The HV power supply unit can also be ordered upon request with a Harting connector as pluggable main connector instead of a fixed mains cable and plug*.
No specific accessories.
For mounting aides and instructions consult us.
*We gladly offer direct assistance for topics around power, cable length and calculations!
All products within this product category:
E3111
/in AC Highvoltage Power Supplies /by adm1n1strat0rE3111 Monitoring HV Power Supply Unit
The power supply unit which detects contamination and monitors operation.
Operation output: +/- 6 kV An intelligent HV power supply unit with good performance wherever more than 1 ionisers are required for neutralisation in a continuous and critical productive use. The E3111 is not only generating the highvoltage for up to 4 antistatic devices with up to 30 m cable length*, but also monitoring the status and neutralisation of the ionizer, as well as maintenance need and sending signals to process control panels !Application
Specialities
+49 7628 35 94 064
We gladly help you to solve your problem.
E3111 Specification
- Power input: 230V AC 50/60Hz; 115V AC 60Hz
- Power consumption: 40VA max.
- Output: max. 5mA at +/- 6 kV
- Auto-shut-down at 5mA; unit switches automatically on when overcharge is reduced
- Illuminated power switch
- Bajonet connectors for up to 4 ionisers
- LED display: contamination control w. 5 level, operation, charge, HV active, malfunction
- Interface with galvanically isolated signal outputs for operations, contamination pre-warning, contamination, malfunction
- Cable length per unit*: max. 30 m minus length of bars x 1,5
- Powder coated steel case IP54 with mounting brackets for walls
- UL, CE and CB certified
Top HV power supply with top performance
Robust, industry-proof design
Easy and flexible mounting
Can be integrated into process control system
Low maintenance
Built-in monitoring system for ionisers and their status
The only device on the market to detect conductive AND non-conductive dirt on the electrodes
Variant ATEX Bars
Variant for EX1250 antistatic bars with ATEX certification
The E3111-EX is designed specifically for the use with the ex-proof Antistatic Bar EX1250. The difference to the standard HV power supply E3111 is only in technical constraints and fuse with regard to the follwong specifications: the E3111-EX is limited to 20 VA power consumption and 5mA output; output voltage is +/- 6 kV with a max. peak at 7,75 kV. The fuses are laid out for 800 mA at 115V and 400 mA at 230 V.
NOTE: the power unit itself is NOT ex-proof and requires installation outside the hazardous area. The max. allowed current for the ATEX certification is 5 mA. Consequently, per power unit a maximum of 30 m cable minus 1,5 times the length of the bar(s)*. This equates for example to:
- 2 antistatic bars of 1 m length and each with 11,5 m cable
- 3 antistatic bars of 1 m length and each with 7 m cable
- 4 antistatic bars of 0,75 m length and each with 5,5 m cable
- etc.
Variant Harting Connector
Variant for powering via Harting connector
The HV power supply unit can also be ordered upon request with a Harting connector as pluggable main connector instead of a fixed mains cable and plug*.
No specific accessories.
For mounting aides and instructions consult us.
We gladly offer direct assistance for topics around power, cable length and calculations!
All products within this product category:
IONTIS Elektrostatik GmbH
Friedrich-Rottra-Str. 66
D-79588 Efringen-Kirchen
- Tel. +49 7628 35 94 064
- Fax +49 7628 35 94 065
- mail@iontis.de
Wir verwenden Cookies. Durch das weitere besuchen dieser Website akzeptieren Sie die Verwendung von Cookies.
Einstellungen akzeptierenNur diese Nachricht verbergenEinstellungenCookie and Privacy Settings
We may request cookies to be set on your device. We use cookies to let us know when you visit our websites, how you interact with us, to enrich your user experience, and to customize your relationship with our website.
Click on the different category headings to find out more. You can also change some of your preferences. Note that blocking some types of cookies may impact your experience on our websites and the services we are able to offer.
These cookies are strictly necessary to provide you with services available through our website and to use some of its features.
Because these cookies are strictly necessary to deliver the website, refuseing them will have impact how our site functions. You always can block or delete cookies by changing your browser settings and force blocking all cookies on this website. But this will always prompt you to accept/refuse cookies when revisiting our site.
We fully respect if you want to refuse cookies but to avoid asking you again and again kindly allow us to store a cookie for that. You are free to opt out any time or opt in for other cookies to get a better experience. If you refuse cookies we will remove all set cookies in our domain.
We provide you with a list of stored cookies on your computer in our domain so you can check what we stored. Due to security reasons we are not able to show or modify cookies from other domains. You can check these in your browser security settings.
These cookies collect information that is used either in aggregate form to help us understand how our website is being used or how effective our marketing campaigns are, or to help us customize our website and application for you in order to enhance your experience.
If you do not want that we track your visit to our site you can disable tracking in your browser here:
We also use different external services like Google Webfonts, Google Maps, and external Video providers. Since these providers may collect personal data like your IP address we allow you to block them here. Please be aware that this might heavily reduce the functionality and appearance of our site. Changes will take effect once you reload the page.
Google Webfont Settings:
Google Map Settings:
Google reCaptcha Settings:
Vimeo and Youtube video embeds:
The following cookies are also needed - You can choose if you want to allow them:
You can read about our cookies and privacy settings in detail on our Privacy Policy Page.
Datenschutzerklärung